Description:

Maxiheat Decromesh Default Flue Kit with inner shield Maxiheat Non Perforated flue kit with inner shield 100 450 100 300 922 992 215 CABINET mm 815 H x 709 W x 592 D APPROX HEAT CAPACITY 200m2 MEDIUM CONSOLE Maxiheat Decromesh Default Flue Kit with inner and outer shields Maxiheat Non Perforated flue kit

Transcription:

K E E P YO U R FA M I LY C O S Y I N,THE COLDER MONTHS WITH. T H E WA R M T H A N D T I M E L E S S,CHARM OF A WOOD FIRE. Clean Air wood heaters feature a unique and advanced firebox designed and. engineered with quality materials for optimum performance Our low emissions and. high efficiencies simply mean that a Clean Air wood heater is the perfect choice. when looking for a quality wood heater to warm your home this winter. Heat exchange Remote controlled 3 speed fan allows. activation tubes you to control the amount of air heat. for greater heat output circulated from your armchair. Side viewing glass provides more,fire viewing area and increases. Double Glazed curved front radiant heat output,door creates a modern look. Removable handle,Natural Convection design, allows the hot air to naturally Skamolex lined firebox pushes.
circulate around the firebox the heat back into the fire. and into the room making it cleaner burning, 15 Y E A R STR U CT U RA L F IR E BOX WA R RA N TY. Every Clean Air wood heater comes with a 15 year firebox structural warranty Each heater is crafted. with quality materials and unrivalled construction for ultimate performance winter after winter. ENVIRONMENT, The range of Clean Air wood heaters are designed to burn hardwood and are tested to the most. stringent of world standards The current joint Australian and New Zealand Standards 4013 4012. measure particulate emissions and efficiency and we are proud to say our heaters exceed the. requirements of these Standards, When you purchase a Clean Air wood heater for your home it will not only give you a modern. clean burning highly efficient method of keeping your home warm throughout winter you are also. making a choice to support Landcare Australia Clean Air wood heaters have been a member of the. Australian Home Heating Association for over 25 years and their membership fees in turn support. Landcare whose working towards restoring the environment and protecting its long term viability. Wood as a form of natural energy is the only sustainable and renewable fuel source for heat. generation Wood burning in a Clean Air wood heater does not add to the greenhouse effect. If wood is left to naturally decay consumed in a bush fire or burnt in a wood heater it emits. similar levels of CO2 Clean Air manufacture slow combustion wood heaters using low emission. technology to gain maximum heat output with minimum emission into the atmosphere. Clean Air 8pg 2019 indd 2 5 4 19 2 07 pm,C L E A N A I R I N S E RT H E AT E R S. STRUCTURAL,F I RE BOX,WA RRAN T Y,SMALL MEDIUM LARGE.
INSERT INSERT INSERT,Coverage 180m Coverage 280m Coverage 330m. Peak Heat Output 9 6 kW Peak Heat Output 12 5 kW Peak Heat Output 15 9 kW. Burn Time up to 7 hours Burn Time up to 8 hours Burn Time up to 9 hours. Efficiency 66 Efficiency 66 Efficiency 62, Emissions 1 0 g kg Emissions 0 8 g kg Emissions 0 7 g kg. Maximum Log Size 340mm Maximum Log Size 390mm Maximum Log Size 420mm. Construction 6mm steel with Skamolex lining Construction 6mm steel with Skamolex lining Construction 6mm steel with Skamolex lining. Firebox Volume 0 05m Firebox Volume 0 07m Firebox Volume 0 1m. All Clean Air Inserts come in a high temperature metallic Black finish and come standard with a Remote Controlled 3 speed fan. Clean Air 8pg 2019 indd 3 5 4 19 2 07 pm,LO N G STRUCTURAL. W I N T ER,Clean Air 8pg 2019 indd 4 5 4 19 2 07 pm. C L E A N A I R F R E ESTA N D I N G H E AT E R S,815H x 709W x 592D mm.
Coverage 200m,Peak Heat Output 12kW,Burn Time up to 7 5 hours. Efficiency 72,Emissions 0 95g kg,Maximum Log Size 340mm. Construction 6mm steel with Skamolex lining,Firebox Volume 0 05m. 865H x 759W x 615D mm,Coverage 300m,Peak Heat Output 14 2kW. Burn Time up to 9 hours,Efficiency 70,Emissions 0 85g kg.
Maximum Log Size 390mm,Construction 6mm steel with Skamolex lining. Firebox Volume 0 07m,915H x 859W x 700D mm,Coverage 350m. Peak Heat Output 19 2kW,Burn Time up to 10 hours,Efficiency 70. Emissions 0 76g kg,Maximum Log Size 420mm,Construction 6mm steel with Skamolex lining. Firebox Volume 0 1m, All Clean Air Inserts come in a high temperature metallic Black finish and come standard with a Remote Controlled 3 speed fan.
Clean Air 8pg 2019 indd 5 5 4 19 2 07 pm,C L E A N A I R H E R I TAG E I N S E RT. The traditional and refined look of the Heritage surround is designed to fit. behind the Clean Air insert heater making it suitable for older style fireplaces. STRUCTURAL, Pictured with optional Clean Air Heritage mantle and Maxiheat Zero Clearance Box. M E D I U M H E R I TA G E L A R G E H E R I TA G E. INSERT INSERT,Coverage 280m Coverage 330m,Peak Heat Output 12 5 kW Peak Heat Output 15 9 kW. Burn Time up to 8 hours Burn Time up to 9 hours,Efficiency 66 Efficiency 62. Emissions 0 8 g kg Emissions 0 7 g kg,Maximum Log Size 390mm Maximum Log Size 420mm.
Construction 6mm steel with Skamolex lining Construction 6mm steel with Skamolex lining. Firebox 0 07m Firebox Volume 0 1m,Clean Air 8pg 2019 indd 6 5 4 19 2 07 pm. Refer to AS NZS,2918 for flue height,requirements,ZERO Flashing. Minimum distance from outer,CLEARANCE casing to any combustible. material 25mm,I N STA L L AT I O N Triple,Brick wall. Transform a dull blank wall into Existing wall lining. a magnificent fireplace with our Front wall cladding. use non combustible material,Zero Clearance models Most.
importantly no major structural,alterations or existing chimney is. required Zero,Installation to AS NZS 2918 2018 minimum box. height of the flue system further than 3m, from the highest point of the roof shall be Floor protector. must use non combustible material,1m above roof penetration. TOP CLEARANCE,APPROX CLEARANCE TO MANTLE,CABINET FASCIA HEAT HEARTH TO MANTLE COLUMN.
mm mm CAPACITY mm mm mm,SMALL 546 H x 608 W x 447 D. 596 H x 750 W 330m2 500 D x 921 W 550 50,ZERO CLEARANCE 817 H x 838 W x 578 D. DISTANCE FROM REAR OF FASCIA TO CENTRE FLUE 268mm,MEDIUM 596 H x 658 W x 487 D. 646 H x 800 W 280m2 550 D x 971 W 550 50,ZERO CLEARANCE 817 H x 838 W x 578 D. DISTANCE FROM REAR OF FASCIA TO CENTRE FLUE 308mm,LARGE 646 H x 758 W x 527 D.
696 H x 900 W 330m2 600 D x 1071 W 550 50,ZERO CLEARANCE 817 H x 838 W x 578 D. DISTANCE FROM REAR OF FASCIA TO CENTRE FLUE 348mm,MEDIUM 546 H x 608 W x 447 D. 765 H x 935 W 330m2 550 D x 971 W 550 50,ZERO CLEARANCE 817 H x 838 W x 578 D. DISTANCE FROM REAR OF FASCIA TO CENTRE FLUE 308mm,LARGE 646 H x 758 W x 527 D. 815 H x 1035 W 330m2 600 D x 1071 W 550 50,ZERO CLEARANCE 817 H x 838 W x 578 D.
DISTANCE FROM REAR OF FASCIA TO CENTRE FLUE 348mm,Clean Air 8pg 2019 indd 7 5 4 19 2 07 pm. REAR SIDE HEARTH MINIMUM DIMENSIONS REAR TO,FLUE CORNERS HEARTH CENTRE. WALL WALL FRONT,KIT mm DEPTH FLUE,mm mm mm WIDTH mm mm mm. FREESTANDING A B C D E F G,Maxiheat Decromesh Default Flue. SMALL Kit with inner shield,100 450 100 300 922 992 215.
CONSOLE Maxiheat Non Perforated flue kit,with inner shield. CABINET mm 815 H x 709 W x 592 D APPROX HEAT CAPACITY 200m2. Maxiheat Decromesh Default Flue,MEDIUM Kit with inner and outer shields. 150 550 200 300 971 995 231,CONSOLE Maxiheat Non Perforated flue kit. with inner shield and outer shields, CABINET mm 865 H x 759 W x 615 D APPROX HEAT CAPACITY 300m2. Maxiheat Decromesh Default Flue,LARGE Kit with inner and outer shields.
250 650 225 300 1071 1180 240,CONSOLE Maxiheat Non Perforated flue kit. with inner shield and outer shields, CABINET mm 915 H x 859 W x 700 D APPROX HEAT CAPACITY 350m2. With all freestanding and inbuilt C,heaters it is imperative to use a. non combustible hearth to protect Standard G Corner F. your flooring and its surrounding Installation F,Installation C. area We recommend following,our minimum hearth clearance D.
diagrams as outlined E, Refer to the product installation manual for final specifications. YOUR AUTHORISED CLEAN AIR DEALER,STRUCTURAL, WA R RANT Y Clean Air wood heaters proudly support the activities of Landcare. Australia through its membership of the AHHA, Building A2 Campus Business Park 350 374 Parramatta Rd Homebush NSW 2140 www cleanairwoodheaters com au P 02 9735 4100. All information is correct to the best of Clean Air Wood Heaters knowledge at the time of printing Clean Air Wood Heaters rely on the reports. from the Testing Authorities in any claim made regarding adherence to Australian Standards and EPA requirements Details provided in this. brochure regarding the installation of a Zero Clearance System are for information purposes only and should not be relied upon as full installation. instructions Heating capacities may vary according to firewood species and moisture content climatic conditions and home construction. individual room or home dimension and installation levels The manufacturer reserves the right to alter design and specifications at anytime. April 2019,Clean Air 8pg 2019 indd 8 5 4 19 2 07 pm.